Please Pay Attention To Install Micro Switch

Oct 26, 2022

When normally CLOSED (NC) contacts are used, the operator must be set to ensure that the drive rod can return to the free position. In addition, when using normally open (NO) contacts, please use 70 to 100% of the specification value of the action stroke (OT) as the standard to install.

When the stroke is set near the action position (OP) and the reset position (RP), the contact force will be unstable and the high reliability cannot be guaranteed. In addition, it is easy to produce false action due to vibration and impact.

When the stroke is set above the total stroke position (TTP), the driving rod and the switch body may be damaged due to the inertia force of the operating body, and the stress added to the internal movable spring will also become larger, resulting in the shortening of the life of the switch