How To Choose A Fuse Holder?
Oct 25, 2022
1. The first function of the fuse is the protection function, that is, when the need to protect the fuse should play a role, which is also the first consideration when we choose the fuse. Under normal circumstances, the rated current of the fuse must be greater than the normal working current of the circuit, and has a certain overload capacity, but if the margin is too large, it will reduce or weaken its protection function, the fuse should not act, causing damage to the protected components or even more serious dangerous consequences. The designer's primary reference tool for selecting a fuse is the "time-current characteristic curve" in the product specification provided by the fuse manufacturer. Since the fuse time reflected in the curve is under normal atmospheric conditions, we also need to consider the influence of ambient temperature when necessary. The protection function of the fuse can be satisfied by selecting the fuse type with proper fuse characteristics and proper rated current specifications.
2. The second function of the fuse is the bearing function, which is commonly known as the pulse resistance ability, which is an important topic that we must consider at the same time when choosing the fuse. In the process of using the fuse, the chance of normal current fluctuation or instantaneous pulse is much more than the fault over current, so in a sense, this aspect of the consideration of the use of the fuse is particularly important and more practical significance. As long as the melting heat energy value of the fuse, I2t, is greater than the energy of the circuit pulse, the fuse can withstand. The "time-melting heat energy curve" is the tool provided to the designer to select the pulse resistance of the fuse (the same can be used in the form of the current-melting heat energy curve). Looking further fuse when subjected to shock pulses even without fusing also will be affected by certain damage, in other words the fuse I2t will decrease, which is the ability of resistance to pulse is reduced, so when choosing the fuse must also consider the attenuation factor, usually simple calculation it needs 3 to 5 times the allowance to ensure that the fuse has enough ability of resistance to pulse. There is a contradiction between the impulse resistance of the fuse and its protection performance. We must find a reasonable balance between the two aspects and find the best joint point. Select fuse specifications with appropriate melting heat energy value and enlarge enough and reasonable safety margin to meet the load bearing function of the fuse (pulse resistance).
3. The third function of a fuse is safety. High quality and reliable fuses should ensure safety before, during and after operation, that is, safe conduction and safe fuse. The main technical index that can guarantee this requirement of fuse is the breaking ability. Breaking capacity is the maximum current at which a fuse can safely cut off a circuit, generally referring to the short circuit current. It is the fuse in the short circuit current must be able to break the circuit absolutely safely, that is, in the process of breaking without any unsafe factors, such as continuous arc, multiple conduction, breakage, splashing, burning, and explosion. The breaking capacity of each fuse must be greater than or equal to the maximum short-circuit current of the protected circuit. The rated voltage of the fuse determines its voltage resistance and is another indicator of the safety performance of the fuse. It can only be used in the circuit where the operating voltage is less than or equal to the rated voltage of the fuse. All countries and regions in the world have safety certification for safety components, fuse safety certification for its safety function is also essential. Select fuse varieties with sufficient breaking capacity and voltage rating, and obtain the necessary application area safety certification, in order to meet the safety function of the fuse.